Fluid Engineering - Test benches

Alternating pressure test

  • 2 different testing circuits
  • Pressures can be chosen flexible between 0 – 20 bar and 0 – 45 bar
  • Temperature range mutable adjustable between +5 °C to +90 °C
  • Temperature, time and pressure profiles are freely programmable

Waterhammer test

  • Pressure range 0 – 20 bar
  • Temperature range mutable adjustable between +5 °C to +90 °C
  • Temperature, time and pressure profiles are freely programmable

Thermal- shock test

  • 2 different testing circuit, temperatures can be used in any combinations (hot-hot, hot-cold, cold-cold)
  • Temperature range mutable adjustable between +5 °C to +90 °C
  • Temperature, time and pressure profiles are freely programmable

Thermo- crash test

Pre-aging test for the simulation of the durability under thermic conditions
  • Pressure range 5 bar
  • Temperature range mutable adjustable from +95 °C to +160 °C

Agingtest

Pre-aging test of material for the simulation of the durability and/or for the analysis of field phenomenas
  • Treatment of the samples with H2O2 – solution
  • Additional analysis

Individual test set-ups

e.g. life test flow sensors with polluted water with concomitant testing of the charactersitic line
  • Flow range: 2 – 10 l/min
  • Temperature range up to +60 °C
  • Water ingredients / degree of pollution selectable